INPUT CHARACTERISTICS:
PSL-6720P(G1)
VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
INPUT CURRENT: 12.0 A FOR 115 VAC, 5.0 A FOR 230 VAC.
INRUSH CURRENT: 75 A MAX. FOR 110 VAC, 150 A MAX. FOR 220 VAC.
OUTPUT CHARACTERISTICS:
LOAD LINE
RIPPLE & NOISE
MAX.[P-P]
5V
5%
1%
60mV
12V
5%
1%
120mV
5%
1%
120mV
5%
1%
120mV
3.3V
5%
1%
60mV
+5VSB
5%
1%
60mV
+5V and +3.3V MAX. power: 230W Total power: 720W (MAX)
*** WHEN PERFORMING CROSS REGULATION TEST, IT IS REQUESTED TO SET THE HIGHER OUTPUT
CHANNEL AT 90% MAXIMUM AND THE LOWER OUTPUT CHANNELS AT 20% MININUM OF RATED
SPEC.
TEMPERATURE RANGE: OPERATING 0
0
C --- 50
0
C, STORAGE –20
0
C --- 80
0
C.
HUMIDITY: 10 ~ 90 % RH.
HOLD UP TIME: 17 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE.
DIELECTRIC WITHSTAND:
PRIMARY TO SECONDARY: 1800 VAC FOR 1 SEC.
PRIMARY TO FG: 1800 VAC FOR 1 SEC.
EFFICIENCY: 71% TYPICAL, AT FULL LOAD, 115VAC.
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms.
OVER LOAD PROTECTION: 110 ~ 150% MAX.
OVER VOLTAGE PROTECTION:
+5V
5.7V ~ 6.3V, 3.3V
3.9V ~ 4.3V, 12V
13.6V ~ 15V.
EMI: MEET FCC CLASS B, CISPR22 CLASS B.
SAFETY: UL 60950, CSA 1402C & CSA950, TÜV EN-60950, CB IEC-60950: 1999, CCC GB4943-2001,
CCC GB9254-1998, CCC GB17625.1-2003
POWER LINE TRANSIENT: EN61000-4-2(ESD) CRITERION B, 4KV BY CONTACT, 8KV BY AIR.
EN61000-4-4(EFT) CRITERION B, 1KV. EN61000-4-5(SURGE) CRITERION B, LINE-LINE 1KV.
ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D
REMOTE ON / OFF CONTROL.
SHORT CIRCUIT PROTECTION: SHUTDOWN AND LATCH.
I
2
C FEATURES (OPTIONAL).
COOLING: ONE 80 mm DC BALL BEARING FAN.
DIMENSION: 86(H) X 150(W) X 220 (D) mm (STRETCH PS/2).