beautypg.com

Wine Guardian Ducted Split Wine Cellar Cooling Systems (WGS175) - Manual User Manual

Page 53

background image

55

Add or remove humidifier

Setting 6

Press “Settings” button to advance

to Setting 6.

Press the up or down arrow buttons

to adjust to the desired set point.

Factory default is zero (0)


One (1) = Integral Wine Guardian
mounted humidifier 一
Two (2) = Stand-alone remote
mounted humidifier

Fan AUTO or ON

Setting 7

Press “Settings” button to advance

to Setting 7.

Press the “Up” or “Down” arrow
buttons to adjust number to the
desired set point. Factory default is
zero (0).

Zero (0) = Auto – fan only turns on

when there is a call for cooling or
heating

One (1) = Fan On – fan remains on

continuously