beautypg.com

Wine Guardian Through-the-Wall Cooling System - Manual User Manual

Page 36

background image

36

Alarm Codes

High temperature
alarm

Press the “Up” or “Down” arrow once to change
screen from alarm to normal Temperature and
Humidity indication. “Hi Temp” will remain on
screen until temperature falls below the High
Temperature Alarm setpoint (Setting 3).





Low temperature alarm

Press the “Up” or “Down” arrow once to change
screen from alarm to normal Temperature and
Humidity indication. “Lo Temp” will remain on
screen until temperature rises above the Low
Temperature Alarm set point (Setting 2).





High humidity alarm

Press the “Up” or “Down” arrow once to change
screen from alarm to normal Temperature and
Humidity indication. “Hi Hum” will remain on screen
until humidity falls below the High Humidity Alarm
setpoint (Setting 5).

Low humidity alarm

Press the “Up” or “Down” arrow once to change
screen from alarm to normal Temperature and
Humidity indication. “Lo Hum” will remain on screen
until humidity rises above the Low Humidity Alarm
set point (Setting 4).

Open Fault

THIS ALARM FORCES THE SYSTEM TO
SHUT DOWN

Press the “Up” or “Down” arrow once to change
screen from alarm to normal Temperature and
Humidity indication.
“Alarm” will remain on screen until the High Pressure
reset switch has been reset. See the trouble shooting
guide page 47 for “Instructions to Reset High Pressure
Switch”