Page 17 of 46

database address is somewhere within the range 00-7F, it may take several
deflections of switch S3 before the next range of addresses is accessed.
Once the desired database has been located, the biased switch S4 should be
deflected to save this setting after a system reset.

Enter the measured target numbers. Fixed #1 and #2 correspond to the
targets where x, y, and height were measured. Fixed #3 corresponds to the
target where only height was measured.

Finally, the name.mkr filename as created in the previous chapter must be
entered in the “Target Data Filename” column.

6.2.2 Camera list

Select: View

Camera List (Alt-V-C)


Measure the offset (x, y, z) between the

free-d

camera and the broadcast

camera optical centres and enter them into the relevant column.


The

free-d

camera

offset

measurements (in meters) consist of
three axes. The X-axis offset should
be 0.0 if the camera is mounted in
the centre of the studio camera. The
Y-axis is the distance from the centre
of the studio lens to the centre of the

free-d

lens; this 30mm above the

white dot printed on all sides of the
camera. If the

free-d

camera is in

front of the lens centre point the

value should be entered as a negative number. Lastly, the Z-axis is the height
of the dot from the centre line of the lens through the studio camera. This
measurement should always be entered as a minus value, for example -0.130.

CCD centre is 30mm above white dot