Installation

CAUTION

SHARP EDGES

RISK OF SERIOUS INJURY

Sharp edges are present inside the Wine Guardian Unit.

Pre-installation Test

Test the unit before installing it to check for non-visible shipping damage.

To test the unit:

√ Set the unit on the floor or a sturdy level surface
√ Plug in the unit
√ Turn on the rocker switch. The switch light comes on. This indicates the unit has power.

The built in timer prevents short cycling and keeps the unit from turning on right

away. To override the timer, open the thermostat cover and simultaneously press the fan
and up arrow buttons. The unit comes on and runs as long as the temperature of the space
is above the thermostat set point. After several minutes, cold air comes out of the unit
from the evaporator section side and hot air comes from the condenser section

.

Listen

for any unusual noise or vibration. (See Air Flow Illustration below)

Air Flow Illustration