QUICK REFERENCE GUIDE

Controller Layout

Refer to page 11 for complete listing of buttons and symbols.

°

F

Compressor On

Fans are On

Unit is in Anti-Frost Mode

Unit is in Pre-Chill Mode

Alarm is Present

°

F

°

F

°

F

°

F

°

F

View Set Point

Change Set Point

(Press and hold 3-5 sec)

Inactive

Power On/Off

Low History

Scroll Button

High History

Scroll Button

Cellar Pre-Chill

(Press and hold 3-5 sec)

Wall Mounted PLATINUM SPLIT UNIT SPECIFICATIONS

Model

4000 Evaporator

(Fan Coil Unit)

4000 Condenser

(Air Cooled

Condensing Unit)

8000 Evaporator

(Fan Coil Unit)

8000 Condenser

(Air Cooled

Condensing Unit)

Cellar Size (cu. ft.)

1000

2000

Dimensions

20.5”w x 15.625”h x

16.0625”d

12”w x 13.5”h x 18”d

20.5”w x 15.625”h x

16.0625”d

12”w x 13.5”h x 18”d

BTUh with 90° air entering

the Condenser Coil

3650

4450

CFM

270

190

278

350

Refrigerant

R-134a

Condensing Unit HP

1/3++

1/2

Voltage Rating

(20 amp

dedicated circuit required)

115V or 230V

Weight (lbs)

56

56

56

66

AMPS

(Starting/Running)

2/1

32.7/7.2

2/1

48/9.5

dBA

54

65

54

65

Drainline

1/2” Condensate

Installation

Evaporator Unit (Fan Coil Unit) is installed in the cellar or up to 25 ducted ft. away, condenser is

installed up to 100 ft from Evaporator Unit (Fan Coil Unit)

Thermostat

Digital Control Display

Temp. Delta

55°F

Temperature differential between the cellar temperature and condenser air intake temperature.

Warranty

2 year parts and labor