TROUBLESHOOTING GUIDE

Unit leaks water

Possible Cause

Solution

Evaporator Unit (Fan Coil Unit) is not level

Evaporator Unit (Fan Coil Unit) should be level on the wall to

prevent leaking.

Drain line clogged or kinked

Check drain line to make sure water can flow freely.

Drain is clogged preventing water form escaping

Disconnect drain and clear out, open access door and check

drain for blockage

Drain line does not have a downward slope

Fix Drain line so there is a downward slope from the unit to the

drain.

Coil is iced causing drain pan ice and water overflowing

Melt ice with blow drier. Soak up with a towel

Unit runs but does not cool

Possible Cause

Solution

Lack of air flow

Make sure fan is unobstructed; Make sure the evaporator filter,

evaporator coil, and condenser coil are clean and free of debris.

System undersized

Contact Customer Service at 800-343-9463

Compressor is overheating

Shut system off for 1 hour to allow compressor to cool. Turn back

on and check for cooler air flow out. If compressor runs, check

for and clean condenser coil as possible cause of compressor

overheating. If problem repeats, contact you installing technician

to assist with troubleshooting.

Evaporator fan runs but compressor does not

Possible Cause

Solution

Running an Anti-Frost Cycle

1) If the system is maintaining the correct cellar temperature

and there is a dripping snowflake symbol illuminated on the

control, the system is going through an anti frost cycle. No action

Required. 2) If the system is not maintaining the correct cellar

temperature this may be caused by a dirty evaporator filter or

coil. 3) Call installing technician to troubleshoot as the system

may be low on charge or an adjustment to the TXV.

Compressor and/or starting components faulty

Please contact the installing technician to troubleshoot.

System may be performing the WHM function

Allow cooling system to revert back to cooling mode.

Compressor may have overheated.

Shut system off for 1 hour to allow compressor to cool. Turn back

on and check for cooler air flow out. If compressor runs, check

for and clean condenser coil as possible cause of compressor

overheating. If problem repeats, contact you installing technician

to assist with troubleshooting.

Compressor runs but evaporator fan does not

Possible Cause

Solution

Faulty fan motor

Please contact the installing technician to troubleshoot.

Faulty Controller

Please contact the installing technician to troubleshoot.

Compressor short cycles

Possible Cause

Solution

System low on refrigerant charge

Please contact the installing technician to troubleshoot.

Condensing fan motor/capacitor faulty

Please contact the installing technician to troubleshoot.

Compressor and /or starting components faulty

Please contact the installing technician to troubleshoot.

Humidity in cellar too low

Possible Cause

Solution

Not enough moisture

Raise the Fon setting to increase the humidity level