Power outages, Error codes – Vintage Cellars CL:DV315MGN3U User Manual

Page 24

background image

24

1. Make sure that the maximum load capacity is not exceeded.

POWER OUTAGES

MOST POW ER OUTAGES ARE RESOLVED IN A SHORT TIME. BECAUSE THE UNITS ARE W ELL
INSULATED, AN OUTAGE OF 1 OR 2 HOURS W ILL NOT ADVERSELY AFFECT THE TEMPERATURES
WITHIN THE CABINET. IN ORDER TO PROTECT THE W INES DURING AN OUTAGE, DO NOT OPEN
THE DOOR (UNLESS REQUIRED). FOR EXTENDED OUTAGES, TAKE STEPS TO PROTECT YOUR
WINE FROM EXTREME TEMPERATURE SW INGS.

ONLY

EXTENDED

EXPOSURE

OF

YOUR

WINES

TO

THESE

ABNORMAL

CONDITIONS

MIGHT

PROVE

DETRIMENTAL

TO

THEM.

ERROR CODES

In spite of high manufacturing standards, quality process control checks and the best quality parts used in all
Climadiff Wine Cellars, the possibility of a technical problem can arise. In order to easily detect any problems, error
codes will be shown on the display.

W

E REMIND YOU THAT ANY ATTEMPTED REPAIR BY A NON QUALIFIED PERSON MAY CAUSE RISKS OF

SERIOUS INJURIES AND MAY VOID THE WARRANTY OF THIS WINE CELLAR

.

A

LSO IT WOULD RELEASE THE

MANUFACTURER AND

/

OR ITS DISTRIBUTORS FROM ANY FURTHER WARRANTY OBLIGATION

.

You will need to communicate to the technician which code is displayed;

Error codes:

E01 :P1
E02 :P2
E03 :P3
E09
E010

P1 = Temperature sensor located at the bottom. It regulates the compressor and the winter heater if this option is
installed.

P2 = Temperature sensor located at the top. It regulates the heater on the top only for MULTI TEMPERATURE
cellars. The top heater is always built in to the Multi-Purpose cellars.

P3 = Hygrometry sensor. It regulates the humidifier if humidifier is built in (based on model)

E01, E02 and E03 means that the sensor is defective or the connection between the PCB of the power module and
the sensor is loose.

E09 means that the safety thermostat switched off the cooling (and heating) because the temperature inside the
cabinet was too low.

When the temperature inside the bottom of the cabinet increases to ~43°F or to the set point, the
compressor will switch on again.

The signal E09 will flash (along with the triangular symbol) until the main supply cord is unplugged (keep
unplugged for 2-3 minutes). After plugging in the main supply cord, the E09 and the flashing triangular
symbol will disappear.

If the temperature is still too low at the bottom of the cabinet the error code and the triangle will appear
again.


E10 means that the communication cable on the PCB of the power module or on the PCB of the display is loose or
the communication cable is defective.