L E C A C H E P R E M I U M W I N E C A B I N E T S

-24-

Alarms

Alarm
Indicators*

The control panel has an audible buzzer and an alarm indicator light
(Row 4) that turns on when an alarm is triggered. In addition, the
control panel will flash the following codes when an alarm is triggered:

Alarm Code

What it means

What to do

P1, P3

Probe Failure

Call CellarPro at 877.726.8496

HA The

temperature

inside the cellar is
too warm (>70°F for
more than 1 hour)

Check seals;

Check if door was left open;

Lower the ambient temperatures

HA2 The

condenser

temperature is too
high (above 125°F for
2 hours)

Check for appropriate installation, ventilation,
ambient conditions and cooling capacity

Clean the condenser coils and/or replace the
air filter;

Check for obstructions to the intake and/or
exhaust vents;

Check that the condenser fan is operating

LA2

The temperature at
the condenser coils
(outside the cabinet)
has dropped below
the alarm
temperature setting

Lower the alarm temperature setting as
follows:
1. Depress the “Set” and “Down” button for

three seconds until the controller displays a
parameter (eg “HY”), then release

2. Depress the “Set” and “Down” button

again for seven seconds until the “PR2”
flashes on the display, followed quickly by a
parameter (eg “HY”), then release

3. Using the “Down” button, scroll until the

display reads “AL2”

4. Depress the “Set” button
5. Use the “Down” button to lower the alarm

temperature setting to 45

6. Depress the “Set” button again
7. After three seconds, the display will return

to the normal screen

* Please note: the temperature alarms (HA, HA2, LA and LA2) are disabled during the first 23
hours of operation after the cooling unit is plugged in and/or turned on.