L E C A C H E P R E M I U M W I N E C A B I N E T S

-22-

Set Button

The cooling unit is factory preset with a
Minimum Set Point of 58°F and a
Temperature Differential of 4°F. This means
that the cooling unit will turn on when the
display rises above 62°F (58°F + 4°F), and
turn off when the display falls below 58°F.

To view the Minimum Set Point, press the
“Set” button for one second.

To change the Minimum Set Point,

1. Press the “Set” button for three seconds

until “°F” blinks

2. Press the “Up” or “Down” button
3. Press the “Set” button to confirm

The “Set” temperature will blink three times
to indicate confirmation.

The recommended Minimum Set Point range
is 53 - 60°F. To change the Temperature
Differential, see “Advanced Operation” later
in this chapter.

Energy Saver Button

To activate and deactivate the “Energy
Saver” mode, press the “Energy Saver”
button

The “Energy Saver” indicator light will turn
on when the cooling unit is in “Energy Saver”
mode

In “Energy Saver” mode, the Minimum Set
Point increases 4°F and the Temperature
Differential is unchanged

Quick Chill Button

To activate the “Quick Chill” mode, press
the “Up” / “Quick Chill” button for three
seconds. To deactivate “Quick Chill”, press
“Quick Chill” button for three seconds again

The “Quick Chill” indicator light will turn on
when the unit is in “Quick Chill” mode.

In the “Quick Chill” mode, the unit will run
continuously for 6 hours (or until the intake
temperature registers 50°F). This mode is
useful after loading “warm” bottles in a cellar