Vintage Cellars Le Cache Cabinet Owners Manual User Manual
Page 10

L E C A C H E P R E M I U M W I N E C A B I N E T S
-9-
Cooling Unit Capacity @ 60°F (1)
BTUH: 1154 Decibels: 42
BTUH: 1479 Decibels: 45
BTUH: 1558 Decibels: 48
Cabinet
Model
Credenza
1400
2400
3100
3800
5200
Ambient
Temperature
Thermal Load
70°F
534
534
598
677
739
828
75°F
606
606
684
767
861
989
80°F
678
678
771
857
983
1151
85°F
750
750
857
948
1107
1311
90°F
822
822
944
1040
1229
1472
95°F
898
898
1035
1136
1357
X
Legend
The tables are shaded to show which cooling units will and won't work given the thermal
load derived from the size of the cabinet and the ambient temperature, as follows:
•
The light-shaded numbers represent thermal loads that are within the capacity of all
CellarPro 1800 cooling units (ie 1800QTL, 1800QT and 1800XT)
•
The medium-shaded numbers represent thermal loads that are within the capacity of
the 1800QT and 1800XT, but not the 1800QTL, cooling units
•
The dark-shaded numbers in italics are within the capacity of the 1800XT cooling unit
•
"X" indicates conditions that are beyond the capacity of our 1800XT cooling unit.
Summary
The following guidelines are designed to assist you in selecting the appropriate CellarPro
wine cooling unit for your Le Cache (or similar size) wine cabinet.
•
is our quietest cooling unit and is appropriate for all but the
largest wine cabinets
•
is slightly louder and can be used most interior environments