5.

Maintenance and care

This chapter gives information about care of Vetter leak sealers
and which maintenance intervals are to be observed.

5.1

Maintenance intervals

A function test of the safety valve must only be carried out wit-
hout the leak sealers. Over-pressure area! A function test of the
safety valve with leak sealers can cause leak sealers to burst.

When?

What?

What to do?

After each

operation

Leak sealers and ac-

cessories

Carry out a check for completeness,

perfect condition and function.

Carry out a visual check and function

check.

Clean the leak sealers with warm water,

neutral cleaning agent and, if necessa-

ry, with a cleaning brush.

Finally, dry at room temperature.

Acid protection

cover

Dispose and replace if necessary.

At least once

every year

Controller

Carry out a visual check and function

check.

Test the function capability of the cou-

plings, nipple, manometer and safety

valve.

At least once

every year

Inflation hose

Carry out a visual check and function

check.

Test the function capability and the

sealing of the connection nipple and

the couplings

At least once

every year

Leak sealers

Carry out a visual check and function

check.

Test the function capability of the con-

nection coupling.

Check for tears and/or cuts, abrasions,

changes to the surface caused by che-

mical effects.