STEP 7: Tighten the RJ45 Feedthru on the cable. If the cable diam-
eter is too small to make a good seal, wrap a couple turns of electrical
tape around the CAT5 cable at the seal area to increase it’s diameter.
STEP 8: Make sure lid gasket is clean and free from any particles,
then carefully close the cover, making sure that wires are clear of the
seam and hinge area.
STEP 9: Tighten the 4 seal screws evenly to seal the cover. Use a
grease or oil on the 4 cover attached screws to make it easier to re-
move later.
TECH CORNER
Additional Information you may find useful
1. CONTROLLER: The controller turns off power to the load at 11V and
reconnects when the battery reaches 12V. This protects battery from
over-discharge and increases battery life and performance.
2. CAPACITY: The RemotePro RPDC12-9-10 is rated at 2.5W contin-
uous power output with 6 hours of peak sun per day. Reserve battery
capacity at 2.5W load is 36 hours. The RPDC12-9-05 is rated at 1.25W
continuous power.
3. VENTING: The enclosure is vented thru a Goretex Vent in the bot-
tom of the enclosure. Don’t cover this vent.
Limited Warranty
The RemotePro™ products are supplied with a limited 24 month war-
ranty which covers material and workmanship defects. This warranty
does not cover the following:
▫
Parts requiring replacement due to improper installation, misuse,
poor site conditions, faulty power, etc.
▫
Lightning or weather damage.
▫
Physical damage to the external & internal parts.
▫
Products that have been opened, altered, or defaced.
▫
Water damage for units that were not mounted according to user
manual.
▫
Usage other than in accordance with instructions and the normal
intended use.