3

generating heat, the fan may run longer to compensate for the internal

heating.

3. FILTER MESH: The stainless steel filter mesh should be small

enough to keep out most insects but will allow dust to enter. If the unit

will be used in dusty areas, we recommend adding a dust cover over

the existing filter mesh. A square piece of filter material can be cut and

fastened over the existing filter mesh using Velcro. The unit should be

checked periodically for clogged filters and they should be cleaned if

clogged to maintain best performance. The stainless steel filter mesh

can be removed with two screws and cleaned with water.

4. FAN DIRECTION: The fan is setup to blow air towards the inside of

the enclosure. This is done to maintain a slightly higher pressure inside

the enclosure when the fan is running. This helps to reduce the humidi-

ty inside the enclosure.

5. WATER INGRESS: The RPST-PowerVent is mounted to the bottom

of the enclosure so in normal use water won’t be able to make it’s way

inside the enclosure. If mounted close to the ground or near lawn sprin-

klers or irrigation sprinklers it’s possible for water to enter the enclosure

through the filter mesh. Be careful about site preparation when using

the RPST-PowerVent. Do not use if the bottom of the enclosure will be

subjected to spraying water.