SPECIFICATIONS

TECH CORNER

Additional Information you may find useful

1. THERMOSTAT: The thermostat will turn on the fan when tempera-

ture at the thermostat reaches 50C (122F). The fan will turn off when

the temperature falls below 40C.

2. COOLING: The fan should bring the interior of the enclosure to ambi-

ent temperature within about 5 mins. If the enclosure is seeing strong

solar heating, the fan may need to run longer to compensate for the

additional heat from the sun. If there is equipment inside the enclosure

Voltage Requirements

12VDC

Power Requirements

1W @ 12VDC – when temperature over 50C

(122F)

Power Connection

1 meter 22AWG 2 Conductor red/black wire

Fan Air Volume

14 CFM min

Filter Mesh x 2

Stainless Mesh - 0.050” Openings

Cable Ports

20mm holes x 4 for Cable Gland

Mounting

8 Existing Screws in Enclosure Bottom Plate

Operating Temperature

-30C to +65C (-22F to 149F)

Humidity

(RH)

5% - 95% (non-condensing)

Dimensions

(LxWxH)

330 x 91.4 x 38mm (13” x 3.6” x 1.5”)

Weight

430g (15 oz)