Specifications tech corner – Tycon Power RPST-PowerVent User Manual
Page 2
2
SPECIFICATIONS
TECH CORNER
Additional Information you may find useful
1. THERMOSTAT: The thermostat will turn on the fan when tempera-
ture at the thermostat reaches 50C (122F). The fan will turn off when
the temperature falls below 40C.
2. COOLING: The fan should bring the interior of the enclosure to ambi-
ent temperature within about 5 mins. If the enclosure is seeing strong
solar heating, the fan may need to run longer to compensate for the
additional heat from the sun. If there is equipment inside the enclosure
Voltage Requirements
12VDC
Power Requirements
1W @ 12VDC – when temperature over 50C
(122F)
Power Connection
1 meter 22AWG 2 Conductor red/black wire
Fan Air Volume
14 CFM min
Filter Mesh x 2
Stainless Mesh - 0.050” Openings
Cable Ports
20mm holes x 4 for Cable Gland
Mounting
8 Existing Screws in Enclosure Bottom Plate
Operating Temperature
-30C to +65C (-22F to 149F)
Humidity
(RH)
5% - 95% (non-condensing)
Dimensions
(LxWxH)
330 x 91.4 x 38mm (13” x 3.6” x 1.5”)
Weight
430g (15 oz)