Page 76: Fault_not_implemented_for_this_protocol – 407h, Fault_protocol_invalid_write_data – 408h, Fault_protocol_invalid_address – 409h, Fault_protocol_write_failed – 406h 76, Fault_not_implemented_for_this_protocol – 407h 76, Fault_protocol_invalid_write_data – 408h 76, Fault_protocol_invalid_address – 409h 76

Protocol Faults
76
Appendix A: Error Messages
FAULT_PROTOCOL_WRITE_FAILED – 406h
Cause
An attempt to modify the contents of a tag failed. There are many reasons for failure.
Solution
Check that the tag is good and try another operation on a few more tags.
F
AULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h
Cause
A command was received which is not supported by a protocol.
Solution
Check the documentation for the supported commands and protocols.
FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h
Cause
An ID write was attempted with an unsupported/incorrect ID length.
Solution
Verify the Tag ID length being written.
FAULT_PROTOCOL_INVALID_ADDRESS – 409h
Cause
A command was received attempting to access an invalid address in the tag data address
space.
Solution
Make sure that the address specified is within the scope of the tag data address space
and available for the specific operation. The protocol specifications contain information
about the supported addresses.