Smart Power Systems HR-30 (3-Phase) User Manual
Page 50
Smart Power
®
Systems
A. C. MODULAR GENERATOR SYSTEM
Page 49 of 52
2.
2. Adjust pump compensator:
a. Reference Figure 30.
b. Loosen the flow control pressure jam nut.
c. While monitoring the generator’s output voltage, slowly rotate the flow control
set screw with a 4mm hex wrench. Adjust the flow control until the generator’s
output frequency is 63 Hz.
d. While keeping the setscrew from rotating, with the hex wrench, re-tighten the
jam nut.
Pump assembly
Figure 30