Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 29 of 52

Operation


1.

The Command & Control Center will show the generator’s output voltage,
frequency, current, and system run time whenever the Command & Control Center
is in the Normal mode. To access Normal mode, press the Mode switch repeatedly
until the correct information is displayed (reference Figure16).

Example of Command & Control Center in Normal Mode

Figure 16



2.

The PTO driving the SPS hydraulic pump must be engaged for the system to
generate electricity.


3.

The Command & Control Center is equipped with two Smart Touch

®

switches,

labeled “Mode” and “On/Off” respectively. These switches do not require pressure
to be activated, but instead sense the presence or absence of your fingertip. The
decimal points in the “Amps Line 1” and “Amps Line 2” fields of the Command &
Control Center are used to indicate the status of the Mode and On/Off switches
respectively (reference Figure 17).

Mode Switch Status Light

On/Off Switch Status Light

Switch Status Lights

Figure 17