Cell voltage monitor & logger celllog 8s, Quick start – ProgressiveRC 8S CellLog User Manual
Page 8

-8-
Cell Voltage Monitor & Logger CellLog 8S
TYPE
XXXXXXXXXX
LOGS
0
RATE
:2.0
[2016Kb/35h:50]
Logs OFF
QUICK START
CellLog Power On Rec. Interval
(2 ways: one is connecting the battery through the left 9 Pin socket, the other one is through the USB port),
System self-check, and then shows the SN and version number, the display information are as below:
The first line is the current selected Setting Type (See
detail in P10). The second line shows the log file number.
And the third line is the available record of capacity and
time. The last line shows the current log file name (if no
files, it shows "Logs OFF"). 3 seconds later, the system
enters to voltage monitor status.
Voltage Monitor
There are 4 interface choices, which can be shifted by <▲> or <▼>buttons.
As the left pictures: the ‘7‘ in ‖7S‖ means cell counts; ‘6H‘
means the 6
th
cell voltage is the highest; ‘1L‘ means the 1
st
cell voltage is the lowest.
If the monitor voltage trigger alarm, the corresponding
voltage and alarm display (LOW, OVER or DIFF) shows
alternatively.
The cell number and (L, O, D) shows alternatively.
‘LOW‘ or ‗L‘ means: Low voltage alarm
‘OVER‘ or ‗O‘ means: Over voltage alarm
‘DIFF‘ or ‗D‘ means: Voltage difference alarm. They will be
displayed at the same time at the highest and the lowest
cell voltage interface.
Monitor the pack voltage
Display respectively: Current pack voltage, Max. Pack
voltage, Min. Pack voltage, Pack voltage difference. (▣P =
HV-LV
)
Data Logging
When in Voltage Monitor status, press <▼> button for 3 seconds, after it shows ‖Start logging…‖, the
calculagraph will be shown alternatively at the upper right corner of the LCD screen. In this status, the system
will transmit the voltage data to USB port every X seconds( this interval time X can be set by user himself,
details you can see Record Interal Time Setting in P13), and save these data to the current Log file(See
Log File Management in P12. If 【Logs OFF】, the system will not log file)
Press <▼> for 3 seconds again, the screen will show ‖Stop logging!‖ and then exit.
View Logging Point
In the monitor status, press <▲> and <▼> at the same time to enter the view logging point status.
Three points voltage data can be searched:‖Starting logging…‖data, ‖Stop logging!‖ data, and the data of
voltage alarm during this period , which can be shifted by < > buttons. Press < > for 3 seconds,it will return
to the monitor status.
The saved data can be covered till next logging.
If the logging time is over the users setting safety time,(See Monitor Safety Time Setting in P11), it will
trigger Safety Time Alarm, and the screen shows ‖T_OVER‖ alternatively in the upper right corner.
Alarm configuration Name
Existent Log Files Number
Free Capacity/Free Time
Current Log File Name
1234567-
7S
28.79
6H
4.162
1L
4.013
▣
V
149mV
Pack Voltage
The highest voltage
The lowest voltage
The maximum
voltage difference
Cell Number
Voltage
Histogram
1
4.013V
2
4.150V
3
4.110V
4
4.152V
5
4.087V
6
4.162V
7
4.120V
8
------
Cell Voltage
Cell Number
7S
28.79V
▣
V
149mV
1
4.01
2
4.15
3
4.11
4
4.15
5
4.08
6
4.16
7
4.12
8
----
Pack Voltage
The Max. Voltage
difference
Cell Number
Cell Voltage
7S
28.79V
HV
28.80V
LV
28.78V
▣
P
0.020V
Pack Voltage
Max. Pack Voltage
Min. Pack Voltage
Pack Voltage Difference
<▢>
<▼>
<▢>
<▼>
<▢>
<▼>
Record interval time