Cell voltage monitor & logger celllog 8s – ProgressiveRC 8S CellLog User Manual
Page 13

-13-
Cell Voltage Monitor & Logger CellLog 8S
SYSTEM SETTING
Beep Tone
LCD Screen
ALM Output
BEEP TONE
Key Tone
Hint Tone
Alarm Tone
Brightness
-
■■■■■■
+
Contrast
-
■■■■■■
+
ALARM OUTPUT
⊙NO.
○NC.
START SETTING
Start Music
Logo Screen
Inf.Screen
RECORD INTERVAL
(0.5-60Seconds)
2
Interval Time
System Settings: Select【System…】, press < >, the screen shows:
<▲> or <▼> to select items, press < > to have a select item, press
< > for more than 3 seconds to return.
See details below.
1) Beep Tone Settings: Select【Beep Tone】, press < >, the screen shows:
<▲> or <▼> to select the items, and press < > to shift select /,
press < > for 3 seconds to confirm the amendment and then return.
Select【Key Tone】,the buttons tone open.
Select【Hint Tone】,the status tone open.
Select【Alarm Tone】,the alarm tone open. (have a ―Do‖ every 4
seconds)
2) LCD Brightness & Contrast Setting : Select【LCD Screen】, press < >, the screen shows:
<▲> increase, <▼> decrease, and press < > to shift
Brightness/Contrast, press < > for 3 seconds to confirm the
amendment and then return.
3) Alarm Output Signal Type Setting:【ALARM Output】
【
NO.】: Always On. Two output of ALM, it‘s open when there is no
alarm; It‘ short circuit with alarm.
【
NC.】: Always Close. Two output of ALM, it‘s short circuit when there
is no alarm; It‘s open with alarm.
4) Record Interval Time Setting:【Rec. Interval】
<▲> or <▼> to increase/decrease, press < > to confirm amendment
and return. Press< > for 3 seconds to cancel amendment and return.
Setting range:0.5-60 Seconds
5) Start-up Setting:【Start…】
<▲> or <▼> to select the items, and press < > to shift select /,
press < > for 3 seconds to confirm the amendment and then return.
Select【Start Music】, there will be a start music if you turn on
Select【Logo Screen】, it will display Logo Screen if you turn on
Select【Inf. Screen】, it will display Information Screen if you turn on