Cell voltage monitor & logger celllog 8s, Monitor alarm settings – ProgressiveRC 8S CellLog User Manual
Page 10

-10-
Cell Voltage Monitor & Logger CellLog 8S
SELECT TYPE
⊙LiPo
○Lilo
○LiFe
LiPo
Rename
New Name
LiPo-1200mAh
ALARM SETTING
Cells Voltag
Pack Voltage
Safety Timer
Alarm Trigger
LiPo
Select
Rename
Alarm
PACK ALARM VOLT
HV
43.00V
LV
1.000V
▣
P
42.00V
Pack Alarm Upper Limit
Pack Alarm Lower Limit
Pack Alarm Difference
CELLS ALARM VOLT
HV
4.22V
LV
3.00V
▣
V
500mV
Cell Alarm Upper Limit
Cell Alarm Lower Limit
Cell Alarm Difference
Monitor Alarm Settings
The system can have 8 sets alarm settings, press <▲> for 3 seconds to enter SELECT TYPE menu.
The item with is the current setting.
<▲> or <▼> to select items and press < > button.
Defaulted TYPEs are: LiPo, Lilo, LiFe, User1--5
Operate the selected type settings
<▲> or <▼> to select the items, press < > to enter to the next step.
See details below.
Note:
Press<▲> button to power on, it will shift to LiPo Type automatically.
Press <▼> button to power on, it will shift to Lilo Type automatically.
Press < > button to power on, it will shift to LiFe Type automatically.
Change Current Alarm Type: Select【Select】, Press < > then the item will be with , and the settings
come into effect.
Rename Alarm Type: Select【Rename】, press < > and the screen shows:
New Name Input Method: <▲> to select characters, hold it to trigger
continuously; <▼> to delete the current character; < > to confirm the
selected character; press < > for 2 times to confirm the amendment
and return; press < > for 3 seconds to cancel and return.
Alarm Parameters Setting: Select【Alarm】, press < > and the screen shows:
<▲> or <▼> to select items, press < > enter to the next step
See details below.
1) Individual Cell Voltage Alarm Settings: Select【Cells Voltage】, press < > and the screen shows:
<▲> or <▼> to increase/decrease voltage value, press < > to shift
setting items. Press < > for 3 seconds to confirm amendment and
return.
HV
: 1.31V—4.90V LV: 1.30V—4.89V ▣V: 0.01—3.60V
2) Pack Alarm Voltage Setting: Select【Pack Voltage】, press < > and the screen shows:
<▲> or <▼> to increase/decrease voltage value, press < > to shift
setting items. Press < > for 3 seconds to confirm amendment and
return.
HV
: 1.05V—43.00V LV: 1.00V—42.95V ▣P: 0.05—42.00V
< >