R s p - 2 0 0 0, 2000w single output power supply – ProgressiveRC RSP-2000 series User Manual
Page 5
5.Current Sharing with Remote Sensing
RSP-2000 has the built-in active current sharing function and can be connected in parallel to provide higher output power :
(1)Parallel operation is available by connecting the units shown as below.
(DA,DB and GND are connected mutually in parallel).
(2)Difference of output voltages among parallel units should be less than 2%.
(3)The total output current must not exceed the value determined by the following equation.
(4)In parallel operation 4 units is the maximum, please consult the manufacturer for applications of more connecting in parallel.
(5)The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
(6) Under parallel operation, the minimum output load should be greater than 5% of total output load.
(7) Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the
output load is more than 5%.
(8) CN502/CN504 Function pin connection
V is CN502/CN504 connected to plug pin, X is CN502/CN504 not connected to plug pin.
Parallel
CN502
CN502
CN502
CN502
CN504
CN504
CN504
CN504
PSU1
PSU2
PSU3
PSU4
1 unit
X
X
X
X
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
2 unit
3 unit
4 unit
(output current at parallel operation)=(Rated current per unit) (Number of unit) 0.9
DA
DA
DA
DA
DA
DA
DA
DA
DB
DB
DB
DB
DB
DB
DB
DB
GND
GND
GND
GND
GND
GND
GND
GND
PSU1
RSP-2000
RSP-2000
RSP-2000
RSP-2000
PSU2
PSU3
PSU4
+V
Sense lines should
be twisted in pairs
-V
LOAD
TB1
TB1
TB1
TB1
CN502
CN502
CN502
CN502
CN504
CN504
CN504
CN504
-V
-V
-V
-V
+V
+V
+V
+V
1
1
1
1
2
2
2
2
5
5
5
5
6
6
6
6
3
3
3
3
1
1
1
1
5
5
5
5
PSU1 CN502
PSU2 CN502
PSU3 CN502
PSU4 CN502
Fig 6.1
GND
(pin5)
DB(pin3)
DA(pin1)
2
2
2
2
4
4
4
4
6
6
6
6
2000W Single Output Power Supply
R S P - 2 0 0 0
s e r i e s
File Name:RSP-2000-SPEC 2011-12-27