beautypg.com

R s p - 2 0 0 0, 2000w single output power supply, Function manual – ProgressiveRC RSP-2000 series User Manual

Page 4

background image

Function Manual

1. Remote ON/OFF Control

The PSU can be turned ON/OFF together or separately by using the "Remote ON/OFF" function.

The remote sense compensates voltage drop on the load wiring up to 0.5V.

Between ON/OFF and +5V-AUX

SW Open

SW Short

PSU Output

ON

OFF

+5V-AUX

ON/OFF

RSP-2000

7

SW

11

2. Remote Sense

-V

+V

RSP-2000

+S

-S

LOAD

-V

+V

1

2

Sense lines should be twisted in pairs

(1)Output voltage can be trimmed between 40~115% of its rated value by the following method.

(2)+S & +V, -S & -V also need to be connected on CN501.

3. Output Voltage Trimming

30

40

60

OUTPUT

VOL

T

A

GE(%)

EXTERNAL VOLTAGE (DC)

80

100

115

Vout

0.4

0

12V

24V,48V

1

2

3

4

4.7

5

V

40

60

80

100

115

V

100

40

60

87

20

OUTPUT

CURRENT

(%)

OUTPUT VOLTAGE (%)

20

Non-Linear

Function

DC-OK

DC-NG

T-OK

T-ALARM

LED

GREEN

RED

RED

GREEN

Description

When output voltage

80%

5% of Vo rated.

When output voltage

80%

5% of Vo rated.

When the internal temperature (TSW1 & TSW2 short) is within safe limit

When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm

4. Front Panel Indicators & Corresponding Signal at Function Pins

Signal

0 ~ 0.5V

4.5 ~ 5.5V

0 ~ 0.5V

4.5 ~ 5.5V

PSU Output

ON

ON

ON

OFF

*

*Signal between function pin and "GND-AUX".

PV

-S

-V

+V

+S

RSP-2000

3

2

1

0~5V

GND

4

LOAD

2000W Single Output Power Supply

R S P - 2 0 0 0

s e r i e s

File Name:RSP-2000-SPEC 2011-12-27

PV / VOLTAGE

MODEL

RSP-2000-12

RSP-2000-24

RSP-2000-48

<0.4V

1V

2V

3V

4V

4.7V

100%

60%

60%

80%

100%

115%

100%

40%

60%

80%

100%

115%

100%

40%

60%

80%

100%

115%