beautypg.com

R s p - 2 0 0 0, 2000w single output power supply, Derating curve static characteristics – ProgressiveRC RSP-2000 series User Manual

Page 3: Efficiency vs load (48v model), Derating load(%) vs input voltage

background image

Derating Curve

Static Characteristics

L

O

A

D(

%

)

INPUT VOLTAGE (VAC) 60Hz

90

100

115

180

24V,48V

12V

264

90

100

80

70

75

65

50

40

AMBIENT TEMPERATURE (

)

L

O

A

D(

%

)

3

4

GND

PV

This pin connect to the negative terminal(-V).

Connection for output voltage trimming. The voltage can be trimmed within its defined range. (Note.1)

7

ON/OFF

The unit can turn the output on and off by electrical signal or dry contact. (Note.2)

8,9,10

GND-AUX

Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V).

230VAC
Input only

-35

-25

0

-10

15

30

50

60

70

20

40

60

50

80

100

(HORIZONTAL)

Pin No.

Pin No.

1,2

1,2

5,6

3,4

Function

Function

DA

Terminal

resistance

GND

DB

Description

Description

Differential digital signal for parallel control.

CN504 is the selector of terminal resistor that is designed for DA/DB signals and parallel control function.

Differential digital signal for parallel control.

These pins connect to the negative terminal (-V).

80

82

84

86

88

90

92

94

10

20

30

40

50

60

70

80

90

100

EFFICIENCY vs LOAD (48V Model)

E

F

F

IC

IE

N

C

Y

(%

)

LOAD

DERATING LOAD(%) VS INPUT VOLTAGE

INPUT / VOLTAGE

MODEL

RSP-2000-12

RSP-2000-24

RSP-2000-48

180VAC

100%

100%

100%

115VAC

95%

80%

80%

100VAC

90%

75%

75%

90VAC

80%

65%

65%

2000W Single Output Power Supply

R S P - 2 0 0 0

s e r i e s

File Name:RSP-2000-SPEC 2011-12-27

Function D

of CN501

escription

Function D

of CN502

escription

Function D

of CN504

escription

Pin No.

1

2

5

6

11

12

Note1: Non-isolated signal, referenced to the output terminals (-V).
Note2: Isolated signal, referenced to GND-AUX.

Function

DC-OK

+S

-S

T-ALARM

+5V-AUX

+12V-AUX

Description

High : When the Vout

80% 6%. Low : When Vout

80% 6%. (Note.2)

Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be

Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be

High : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm.
Low : When the internal temperature (TSW1 or TSW2 short) under the limit temperature.

(Note.2)

Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin ). The maximum load current is 0.3A. This output has the

Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX (pin ). The maximum load current is 0.8A. This output has

twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.

twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.

built-in "Oring diodes" and is not controlled by the remote ON/OFF control.

the built-in "Oring diodes" and is not controlled by the remote ON/OFF control.