Outsideglz-frm-install, Outside glaze frame installation – Oldcastle BuildingEnvelope FG-3000 User Manual
Page 9

OUTSIDE GLAZE
FRAME INSTALLATION
FG-1122 X 4" LONG
(PART SOLD IN STOCK LENGTHS.)
1. ASSEMBLY WITHOUT FLASHING
IS NOT RECOMMENDED.
2. DO NOT ANCHOR WALL THRU
VERTICAL LEG OF FLASHING.
SEALANT
ACCESS HOLE AT ALL ANCHOR LOCATIONS.
(SIZE DETERMINED BY ANCHOR.)
DRILL CLEAR HOLE IN FLASHING THOUGH
ANCHOR CLIP. THEN INJECT SEALANT INTO
HOLE IN FLASHING AND UNDER ANCHOR CLIP.
ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS.
SILL ANCHOR FG-2000-FP-3 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED SO THAT
THE ANCHOR IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.
FG-2000-FP-3
PART #: 7944
FG-2188
PVC PROFILE
USED TO IMPROVE
INSTALLATION OF
BACKER ROD AND
PERIMETER SEALANT.
(OPTIONAL)
CLEAR HOLE
(SIZE DETERMIMED BY ANCHOR.)
8
JULY 2011
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L