INSIDE GLAZE
SILL FLASHING INSTALLATION
1. ANCHORS DESIGNED TO TWIST IN.
2. SPACE ANCHORS MAX. 4" FROM
EACH SIDE OF MULLION.
3. BENT LEG ALWAYS TO EXTERIOR.
4. NOTE: STAKE ANCHORS TO PREVEN
T
HORIZONTAL MOVEMENT.
ANCHORS MUST FACE EXTERIOR
AS SHOWN.
INTERIOR
A SHIM UNDER FLASHING
IS THE PREFERRED METHOD
FOR BEST THERMAL RESULTS.
FLASHING ANCHORS MUST
BE CAP SEALED.
SEALANT
FG-3217
FG-3000-FP-4
PART #: 7947
FG-3000-FP-3
PART #: 7948
FG-3000-FP-11
PART #: 7979
1/4" NOM.
SEAL WITH A NON-SKINNING,
NON-HARDENING SEALANT.
FILL BREAK IN FLASHING
AND UNDER SPLICE.
NOTE: SILL FLASHING
SHOULD BE LEVEL AND
MAKE SURE IT IS NOT TILTED
TOWARD THE INTERIOR.
FLASHING SPLICE