INSIDE GLAZE
FRAME INSTALLATION
FG-3000-FP-3
PART #: 7948
FG-3217
FG-2188
PVC PROFILE
USED TO IMPROVE
INSTALLATION OF
BACKER ROD AND
PERIMETER SEALANT.
(OPTIONAL)
FG-2122 X 4" LONG
(PART SOLD IN STOCK LENGTHS.)
CLEAR HOLE
(SIZE DETERMIMED BY ANCHOR.)
ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS.
SILL ANCHOR FG-3000-FP-3 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED
SO THAT THE ANCHOR SCREW IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.
31
JULY 2011
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com