OUTSIDE GLAZE SILL FLASHING
INSTALLATION AND PERIMETER SEAL
APPLY SEALANT ALONG LENGTH OF SUB SILL
AT AREAS A & B.
LAY FLASHING ON SLAB AND SHIM ONLY AT LOW
AREAS. RESEAL AT SHIM AREAS.
SPACE BETWEEN SILL AND FLASHING (C) TO BE
CONTINUOUSLY SEALED EXCEPT FOR 1/2"-3/4"
SPACE UNDER VERTICAL MULLIONS FOR WEEPAGE.
PRIOR TO INSTALLING FRAME, APPLY SEALANT
CONTINUOUSLY ALONG SILL FLASHING (D).
THIS WILL PROVIDE CONTINUOUS SEAL
BETWEEN SILL AND SILL FLASHING.
THE QUALITY OF THE INSIDE AND OUTSIDE
PERIMETER SEALS (C AND E) MAY BE IMPROVED
BY USING FG-2188 RIGID PVC FILLER.
THE PART MAY BE USED IN FULL LENGTHS OR CUT
INTO PIECES. ITS PURPOSE IS TO PROVIDE
SUPPORT FOR THE BACKER ROD REGARDLESS
OF JOINT OR SIZE. PERIMETED SEAL (F) IS FOR
COSMETIC PURPOSES AND IS OPTIONAL.
FG-2000-FP-3 PART #: 7944
D
A
C
B
F
NOTE: 1/2"- 3/4" WEEP HOLE
REQUIRED IN SEALANT AT
FLASHING (C)AT CENTER
LINE OF MULLION.
E
E
E
E
FG-2122
4" LONG
(PARTS SOLD IN
STOCK LENGTHS.)