INSIDE GLAZE, NON THERMAL SILL FLASHING
INSTALLATION AND PERIMETER SEAL
APPLY SEALANT ALONG LENGTH OF SUB SILL
AT AREA A.
PRIOR TO INSTALLING FRAME, APPLY SEALANT
CONTINUOUSLY ALONG SILL FLASHING (B).
THIS WILL PROVIDE CONTINUOUS SEAL
BETWEEN SILL AND SILL FLASHING.
THE QUALITY OF THE INSIDE AND OUTSIDE
PERIMETER SEALS (C ) MAY BE IMPROVED BY
USING FG-2188 RIGID PVC FILLER.
THE PART MAY BE USED IN FULL LENGTHS OR CUT
INTO PIECES. ITS PURPOSE IS TO PROVIDE
SUPPORT FOR THE BACKER ROD REGARDLESS
OF JOINT OR SIZE. PERIMETED SEAL (D) IS FOR
COSMETIC PURPOSES AND IS OPTIONAL.
FG-3000-FP-3
PART #: 7948
FG-3210
C
C
C
C
E
A
D
FG-2122
4" LONG
(PARTS SOLD IN
STOCK LENGTHS.)
THIS LEG MUST BE
TO EXTERIOR.
NOTE: 1/4" WEEP HOLE
REQUIRED IN FLASHING (E)
AT MID-LITE.