Install threshold, Figure 1 figure 2 – Oldcastle BuildingEnvelope Thermal Clad Door and Frame User Manual
Page 12

D O O R A N D F R A M E
INSTALLATION INSTRUCTIONS FOR HIGH-PERFORMANCE THRESHOLD
SINGLE
BUTT HINGE OR
OFFSET PIVOT
DOORS
1. Cut the D-118 weather-strip to Door Width
minus 1 1/16" see (fig. 1).
2. Placing the D-118 1-1/16" up from the bottom of the
door rail (fig. 2), center it by overlapping the stiles
equal distances (fig. 1). Using the D-118 as a tem-
plate, mark the door for the attachment holes. Drill
the door for #8 x 1/2" FHSMS, attach the D-118 to
the door and insert the D-120 silicone strip. Crimp
ends.
3. On both frame jambs drill two #29 (.136" dia.) holes
in frame for #FS-256 screws and attach clips to
frame (fig 2). Drill one #2 (.211" dia.) hole 1/2" in
from each end of the threshold as shown in (fig. 2)
and countersink for #12 FHSMS #FS-42. Attach
threshold to clips.
4. Seal threshold to frame and surrounding conditions.
INSIDE
WIDE STILE DOOR
MEDIUM STILE DOOR
NARROW STILE DOOR
1 11/16"
3 5/32"
4 9/16"
DOOR WIDTH MINUS 1 1/16"
1 3/8"
CLIP FOR 4" AND 4 1/2" FRAME
11/16"
Ref.
1 1/16"
2 5/16"
2 3/4"
5/8"
FG-1118
D-120
5/32"
TH-49
D-118 ATTACH WITH #8 SCREW
Figure 1
Figure 2
12
MAY 2012
D O O R & F R A M E
I N S T A L L A T I O N M A N U A L
Web Address: www.oldcastlebe.com
Phone: 1-866-OLDCASTLE (653-2278)