DOOR FRAME INSTALLATION
NOTES:
1) USE SHEAR BLOCKS AS SHOWN IN FRAME ASSEMBLY SECTION OF THIS MANUAL TO SECURE
HORIZONTALS TO TUBULAR FRAMES.
2) DOOR FRAME IS ANCHORED BY FASTENERS THROUGH THRESHOLD AND DOOR FRAME HEADER.
3) DO NOT FABRICATE STANDARD 2 PIECE POUR & DEBRIDGED FRAME EXTRUSIONS FOR DOOR
FRAMES. IF THERMAL FRAME IS REQUIRED,OPTIONAL THERMAL DOOR FRAME FG-3389 MAY BE
USED IN CONJUNCTION WITH OLDCASTLE BUILDINGENVELOPE THERMAL DOORS.
4) WHEN USING THE CENTER SET SYSTEM, THE TWO-PIECE OR TUBULAR FRAMING OPTION ARE
AVAILABLE AS SHOWN ABOVE. WHEN USING EITHER THE FRONT SET OR BACK SET SYSTEM ONLY
THE TUBULAR OPTION IS AVAILABLE. THE VERTICAL FOR THE FRONT OR BACK SET OPTIONS
IS FG-3287.
FG-3156
FG-3155
FG-2145
LEAVE FRONT OF DOOR JAMB
CLEAR OF SEALANT FOR DRAINAGE
BED SUB-SILL IN
SEALANT AT DOOR JAMB
RUN SEALANT MINIMUM 1"
ABOVE BACK OF SUB-SILL
1"