P19 perimeter anchors and seal – Oldcastle BuildingEnvelope 3000 XT Series User Manual
Page 19
![background image](/manuals/638796/19/background.png)
19
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
ANCHOR AND PERIMETER SEAL
C
C
C
C
NOTE: 5/16" WEEP HOLES REQUIRED
IN FLASHING (E) AT CENTERLINE OF
D.L.O.
APPLY SEALANT ALONG LENGTH OF SILL FLASHING AT
POINT (A).
APPLY FILLET SEAL BETWEEN SILL FLASHING AND FRONT OF SILL (B).
THE QUALITY OF THE INSIDE AND OUTSIDE PERIMETER SEALS (C) MAY
BE IMPROVED BY USING FG-2188 RIGID PVC FILLER. THE PART MAY BE
USED IN FULL LENGTHS OR CUT INTO PIECES. ITS PURPOSE IS TO
PROVIDE SUPPORT FOR THE BACKER ROD REGARDLESS OF JOINT SIZE.
INTERIOR PERIMETER SEAL AT SILL (D) IS OPTIONAL AND FOR COSMETIC
PURPOSES ONLY.
FG3000-FP-58
ANCHOR
FG3000-FP-58 AND FG3000-FP-59
ANCHORS ARE DESIGNED TO
CARRY A MAXIMUM END
REACTION OF 600LBS.
C
C
OPTIONAL MO-678/MO-244
HEAD RECEPTOR
MAXIMUM END REACTION
OF 450 LBS.
C
C
A
D
A
E
B
FG-3506 HEAD WITH FG3000-FP-58 ANCHOR
FG-3510 HEAD WITH FG3000-FP-59 ANCHOR
MAY 2013
S E R I E S 3 0 0 0 X T - I N S T A L L A T I O N M A N U A L