GLAZING ADAPTOR INSTALLATION
NOTE:
ADAPTORS SHOULD BE INSTALLED ON INTERIOR
SIDE OF ALL GLAZING OPTIONS.
GLASS
1/4"
5/16"
3/8"
7/16"
1/2"
9/16"
5/8"
5/8"
GLASS
11/16"
3/4"
13/16"
7/8"
15/16"
1"
1 1/16"
1 1/8"
ADAPTOR
FG-3194
FG-3236
FG-3236
FG-3236
FG-3237
FG-3237
FG-3237
NONE
ADAPTOR
FG-3237
FG-3237
N/A
None
None
None
None
None
GASKETS
FG-1133 Both Sides
FL-66 Both Sides
FG-1133 & FL-66
FG-1133 Both Sides
FL-66 Both Sides
FG-1133 & FL-66
FG-1133 Both Sides
FG-3129 Both Sides
GASKETS
FG-1133 & FG-1134
FG-1134 Both Sides
Not Available
FL-66 Both Sides
FG-1133 & FL-66
FG-1133 Both Sides
FG-1133 & FG-1134
FG-1134 Both Sides
SEAL CORNERS OF ADAPTORS. MARRY
ADAPTOR SEAL INTO SEALANT AT
CORNER OF GASKETS.
SEE CHART BELOW FOR CORRECT
GASKET AND ADAPTOR FOR
SPECIFIC APPLICATIONS
BED ADAPTORS IN CONTINUOUS
BEAD OF SEALANT
MAY 2013