DOOR FRAME ASSEMBLY
1. Attach (2) AC-133-01 shear blocks to top end of door jambs using (4) FS-9 #14 x 1 1/2" hex
head fasteners. See FIGURE 1.
2. Attach AD-204-01 left hand or AD-205-01 right hand threshold clips to bottom of door jamb
using (2) FS-62 #10 x 1/4" flat head machine screws. See FIGURE 3, pg 8.
3. Apply sealant along exterior and interior faces of shear blocks as shown in FIGURE 2, pg 8.
4. Assemble door header to jambs by sliding header over shear blocks and attaching using (2)
FS-7 #10 x 3/4" flat head screws. Clean excess sealant from exposed surfaces after assembly.
5. Attach threshold to clips using (1) FS-62 #10 x 1/4" flat head fasteners, See FIGURE 4, pg. 8.
Note; threshold will be removed once frame is installed into opening to seal and drill for
anchors.
6. Assembly of common lock mullions; use (2) AC-130 shear blocks mounted beneath door
header and attach with (4) FS-9 fasteners. Mullion will attach to shear blocks using (4) FS-7
#10 x 3/4" PFH screws. See FIGURE 5, pg 9.
7. Assembly of common hinge mullions; use (4) AC-130 shear blocks mounted beneath door
header and attach with (8) FS-9 fasteners. Mullion will attach to shear blocks using (4) FS-7
#10 x 3/4" PFH screws. See FIGURE 6, pg 10. When using the AD-452 common hinge mullion
between sets of doors, run mullion through and attach AD-450 door header as shown below.
FIGURE 1
Shear block installation
AC-133-01
FS-9
3/8"
5/16"
7/8"
5/16"
7/8"
Drill #11 (.191Ø) holes
AD-452
Common Hinge Mullion
Typical Door Jamb
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
7
MAY 2013
AD-375 THERMAL DOOR
(2) FS-7