FIGURE 2
Shear block sealant
Apply sealant to
shear blocks at interior
and exterior
FS-7
1/2"
7/8"
7/8"
Drill #11 (.191Ø)
Holes & Countersink for
#10 pfh
(2) FS-62
#10 X 1/4" ucpfh
AD-204-01 Left Hand
AD-205-01 Right Hand
Threshold Clips
FIGURE 3
Threshold clip install
FIGURE 4
Threshold installation
FS-62
#10 X 1/4" ucpfh
FRAME ASSEMBLY
Match drill shear blocks
with # 25 (.149) tap holes