Pg12_3000frm assy 2, Ad-375 thermal door – Oldcastle BuildingEnvelope AD-375 Thermal Entrance User Manual
Page 14
Series 3000 XT DOOR FRAME ASSEMBLY
1. Door frame with transom will use AD-454 door jambs, AD-455 door header with AD-406 and AD-407
vertical sash. Transom head may use either FG-3198 or FG-3510 with FG-3210 glass stop.
2. Attach door header to frame using (2) AC-130-01 shear blocks using (2) FS-9 fasteners per shear
block. Door header will attach to shear block with (2) FS-7 #10 x 3/4" pfh fasteners.
3. Transom header will use AC-xxx shear block attached with (2) FS-9 fasteners and xxx dowel pin at
front section of header. Head will be attached to shear block with a FS-7 fastener.
4. Install FG-3220 setting block into top of door header.
5. AD-406 interior door sash will attach to frame with FS-7 fasteners at 18" on center with minimum 3
fasteners. Exterior stop will be hooked in place after glass is installed.
6. FG-1133 gasket will be used on interior and exterior of transom frame.
FIGURE 8
Transom Assembly
3/8"
Drill #11
(.191Ø)
holes
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
12
MAY 2013
AD-375 THERMAL DOOR
(2) FS-7
FS-7 @ 18" O.C.
or Min. 3 fasteners if D.L.O.
is less than 38"
(4) FS-9
(2) FS-9
Roll
Pin
AC-119-1
(2) AC-130-01
AD-406
AD-407
Typ. #25 (.149)
Tap Hole
FG1000-FP-2
1/4"
1-1/4"
29/32"
7/16"
29/32"
1-1/4"