INSTALLATION PAIRS OF DOORS

Located at the meeting stile of the pair of AD-375 thermal doors are three

adjustable astragals. The exterior astragal has a single strip of wool pile

weathering. On the interior is located two astragals on opposing door stiles. These

are a thermal plastic with bulb gasket. Each of these astragals may be adjusted

independently to create an air tight seal. See instructions below for proper

adjustment.

Adjust astragal so that

piles lightly touch at

center of opening

Adjust astragals on each door

equally so bulb gasket lightly touches
at center line of door full length.

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

20

MAY 2013

AD-375 THERMAL DOOR

1. Adjust astragals on each door leaf so that the bulb gasket makes light contact

with inactive leaf bulb for full length of door at centerline.

2. Once astragals are adjusted, apply silicone sealant and tool flat at gap between

astragal and door stile at threshold for 1" to close any gap at this connection.

3. Remove string from wool pile at exterior of door. Then adjust exterior astragal of

active leaf so that the wool pile weather seals lightly touch at center of door
opening.

Seal gap at astragal to door

at threshold with silicone

for 1" after adjustment

1"

Seal gap at astragal to door
at threshold with silicone

for 1" after adjustment