• For the next 2 minutes 220 VAC is sent from terminal 3 on connector X11

through the normally closed auxiliary contacts of contactor K50 to the K5
contactor coil
◊ K5 contactor closes and the motor turns CCW
◊ The normally closed auxiliary contacts on K5 open preventing the K50

contactor from energizing.

NOTE: If the door switch (S7) opens by the door opening, then the fan circuit

is de-energized. Then the motor will be pulsed in the opposite direction to
“break” the fan. This is to stop the fan quicker for the operator.

c The hot air heat circuit is energized

• 220 VAC is sent from terminal 3 of connector X12 on the Control Board

(A10) to the coil of Contactors K41 and K61 until the cabinet reaches the set
temperature as sensed at probe B6.
◊ The Contactors K41 and K61 close and he 220 VAC is sent to the outer

elements (E41 and E61)

• 220 VAC is sent from terminal 7 of connector X11 on the Control Board

(A10) to the coil of Contactors K42 and K62 until the cabinet reaches the set
temperature as sensed at probe B6.
◊ The Contactors K42 and K62 close and 220 VAC is sent to the inner

elements (E42 and E62)

◊ If the reduced power option is chosen then Contactors K42 and K62 are

not energized.

d When the condensate box is heated to 140 degrees F at the B3 probe, 220 VAC is

sent from terminal 5 of connector X12 to the condenser valve (Y1) until the
temperature drops.

e If the “Crisp and Tasty” mode is selected

• 220 VAC is sent from terminal 6 of connector X12 on the Control Board

(A10) to the Dehumidification Valve (Y2) to pull the humidity out of the
cabinet down the drain.
◊ In the light and medium modes (one and two drops in the display) the Y2

valve will be energized until the bypass probe (B5) is satisfied.

◊ In the full mode (3 drops in the display) the Y2 valve will be energized

continuously.

f When the timer counts to 0 or the core temp probe (B10) reaches the set amount

the cycle ends

5 With the combi in the Combi mode with time on the timer, the door closed and the

start switch is depressed
a The front display will include a lighted bar under the combi symbol

• When the heat circuit is energized the heat symbol will be energized

• The cooking mode symbol will be energized.

• The time display will invert and begin to count down.

b The fan circuit is energized

• If the combi fan is in the normal setting 220 VAC is sent from terminal 5 on

connector X11 through the normally closed auxiliary contacts of contactor