The normally closed auxiliary contact of K4 opens preventing the Steam
Contactor K1 from energizing
• 220 VAC is sent from terminal 7 of connector X11 on the Control Board
(A10) to the coil of Contactor K44 until the cabinet reaches the set
temperature.
◊
The contactor K44 closes and the third leg of 220 VAC is sent to the 18
KW element (E4)
◊
If the reduced power option is chosen then the K44 Contactor is not
energized.
d
When the condensate box is heated to 140 degrees F at the B3probe, 220 VAC is
sent from terminal 5 of connector X12 to the condenser valve (Y1) until the
temperature drops.
e
If the “Crisp and Tasty” mode is selected
• 220 VAC is sent from terminal 6 of connector X12 on the Control Board
(A10) to the Dehumidification Valve (Y2) to pull the humidity out of the
cabinet down the drain.
◊
In the light and medium modes (one and two drops in the display) the Y2
valve will be energized until the bypass probe (B5) is satisfied.
◊
In the full mode (3 drops in the display) the Y2 valve will be energized
continuously.
f
When the timer counts to 0 or the core temp probe (B10) reaches the set amount
the cycle ends and the steam generator reverts to the standby temperature of 190-
degree F.
6
With the combi in the Combi mode with time on the timer, the door closed and the
start switch is depressed
a
The front display will include a lighted bar under the combi symbol
• When the heat circuit is energized the heat symbol will be energized
• The cooking mode symbol will be energized.
• The time display will invert and begin to count down.
b
The fan circuit is energized
• If the combi fan is in the normal setting 220 VAC is sent from terminal 5 on
connector X11 through the normally closed auxiliary contacts of contactor
K57 to the coils of contactors K55 and K56
◊
The K55 and K56 contactors close sending 220 VAC through the Q56
overload to the motor and the motor turns at a high speed.
◊
The normally closed auxiliary contacts of both K55 and K56 open
preventing the K57 contactor from energizing.
• If the combi fan is in the reduced setting 220 VAC is sent from terminal 6 on
connector X11 through the normally closed auxiliary contacts of contactors
K55 and K56 to the coil of contactor K57
◊
The K57 contactor closes Sending 220 VAC through the Q57 thermal
overload to the motor and the motor turns at a reduced speed.
◊
The normally closed auxiliary contacts of K57 open preventing the K55
and K56 contactors from energizing.