• If the ground is not found 220 VAC is sent from terminal 7 on connector X12

on the Control Board (A10) to the fill solenoid (Y3)

• The fill solenoid opens and the generator is filled until both probes are

grounded.

If the top probe becomes ungrounded for more that 5 seconds the fill

solenoid (Y3) will energize.

If the bottom probe becomes ungrounded the combi will fill immediately

and the combi will not heat

d

When the terminal 2 on connector X15 is grounded

• 220 VAC is sent from terminal 4 of connector X12 on the Control Board

(A10) through the normally closed auxiliary contacts of K4 to the coil of
Contactor K1 until the steam generator get to 190 degrees F (probe B4).

The contactor K1 closes and 220 VAC is sent to the 9.4 KW element (E1)

The normally closed auxiliary contact of K1 opens preventing the Hot Air

Contactor K4 from energizing

• 220 VAC is sent from terminal 8 of connector X11 on the Control Board

(A10) through the normally closed auxiliary contacts of K44 to the coil of
Contactor K2 until the steam generator get to 190 degrees F (probe B4).

The contactor K2 closes and 220 VAC is sent to the 6.27 KW element

(E2)

The normally closed auxiliary contact of K2 opens preventing the Hot Air

Contactor K4 from energizing

4

With the combi in the steam mode with time on the timer, the door closed and the

start switch is depressed
a

The front display will include a lighted bar under the steam symbol

• When the heat circuit is energized the heat symbol will be energized

• The cooking mode symbol will be energized.

• The time display will invert and begin to count down.

b

The fan circuit is energized

NOTE: If the temperature is less than 212 degrees F than fan will be pulsed

on for 2 seconds every 60 seconds after the cabinet set temp (B6).

• If the combi fan is in the normal setting 220 VAC is sent from terminal 5 on

connector X11 through the normally closed auxiliary contacts of contactor
K57 to the coils of contactors K55 and K56

The K55 and K56 contactors close sending 220 VAC through the Q56

overload to the motor and the motor turns at a high speed.

The normally closed auxiliary contacts of both K55 and K56 open

preventing the K57 contactor from energizing.

• If the combi fan is in the reduced setting 220 VAC is sent from terminal 6 on

connector X11 through the normally closed auxiliary contacts of contactors
K55 and K56 to the coil of contactor K57

The K57 contactor closes Sending 220 VAC through the Q57 thermal

overload to the motor and the motor turns at a reduced speed.

The normally closed auxiliary contacts of K57 open preventing the K55

and K56 contactors from energizing.