Cp305 introduction – Kontron CP305 User Manual
Page 35
CP305
Introduction
ID 1035-7168, Rev. 2.0
Page 1 - 15
P R E L I M I N A R Y
In addition, boards providing ruggedized service comply with the following standards as well.
Furthermore, boards providing ruggedized service and conformal coating comply with the fol-
lowing standards as well.
Table 1-4:
Additional Standards for Boards with Ruggedized Service
TYPE
ASPECT
STANDARD
REMARKS
Environmental
Vibration
(Sinusoidal)
IEC60068-2-6
Ruggedized version test parameters:
• 10-300 (Hz) frequency range
• 5 (g) acceleration
• 1 (oct/min) sweep rate
• 10 cycles/axis
• 3 axis
Single Shock
IEC60068-2-27
Ruggedized version test parameters:
• 30 (g) acceleration
• 9 (ms) shock duration half sine
• 3 number of shocks per direction (total: 18)
• 6 directions
• 5 (s) recovery time
Permanent Shock
IEC60068-2-29
Ruggedized version test parameters:
• 15 (g) acceleration
• 11 (ms) shock duration half sine
• 500 number of shocks per direction
• 6 directions
• 5 (s) recovery time
Table 1-5:
Add. Standards for Boards with Ruggedized Service and Conformal Coating
TYPE
ASPECT
STANDARD
REMARKS
Railway
Electromagnetic Com-
patibility (EMC)
EN50155
--
EN50121-3-2
--
Temperature
EN50155
Class T2
Shock and Vibration
EN50155
--
EN60373
Class 1B
Climatic Humidity
EN50155
--