8 standards, Standards - 14, Introduction cp305 – Kontron CP305 User Manual
Page 34

Introduction
CP305
Page 1 - 14
ID 1035-7168, Rev. 2.0
P R E L I M I N A R Y
1.8
Standards
This Kontron product complies with the requirements of the following standards.
Table 1-3:
Standards
TYPE
ASPECT
STANDARD
CE
Emission
EN55022
EN61000-6-3
Immission
EN55024
EN61000-6-2
Electrical Safety
EN60950-1
Mechanical
Mechanical Dimensions
IEEE 1101.10
Environmental
Climatic Humidity
IEC60068-2-78
(see note below)
WEEE
Directive 2002/96/EC
Waste electrical and electronic equipment
RoHS
Directive 2002/95/EC
Restriction of the use of certain hazardous sub-
stances in electrical and electronic equipment
Note ...
Kontron performs comprehensive environmental testing of its products in accor-
dance with applicable standards.
Users desiring to perform further environmental testing of Kontron products
must contact Kontron for assistance prior to performing any such testing. This is
necessary, as it is possible that environmental testing can be destructive when
not performed in accordance with the applicable specifications.
In particular, for example, boards without conformal coating must not be
exposed to a change of temperature exceeding 1K/minute, averaged over a
period of not more than five minutes. Otherwise, condensation may cause per-
manent damage, especially when the board is powered up again.
Kontron does not accept any responsibility for damage to products resulting
from destructive environmental testing.