beautypg.com

4 electrical specification, 5 environmental specification, 6 mtbf – Kontron COMe Eval Carrier T2 User Manual

Page 10

background image

COM Express® Eval Carrier Type 2

9

3.4 Electrical Specification

Supply Voltage

»

ATX Main Power 24pin

Power Supply Rise time

»

The input voltages shall rise from ≤10% of nominal to within the regulation ranges within 0.1ms to

20ms.

»

There must be a smooth and continuous ramp of each DC input voltage from 10% to 90% of its final set-

point following the ATX specification

Supply Voltage Ripple

»

Maximum 100 mV peak to peak 0-20MHz

3.5 Environmental Specification

Ambient temperature

»

Operating: 0 to +60 °C

»

Non-operating: -30 to +85 °C

Humidity

»

Operating: 10% to 90% (non condensing)

»

Non operating: 5% to 95% (non condensing)

3.6 MTBF

The following MTBF (Mean Time Between Failures) values were calculated using a combination of manufacturer’s
test data, if the data was available, and a Bellcore calculation for the remaining parts. The Bellcore calculation
used is “Method 1 Case 1”. In that particular method the components are assumed to be operating at a 50 %
stress level in a 40° C ambient environment and the system is assumed to have not been burned in.
Manufacturer’s data has been used wherever possible. The manufacturer’s data, when used, is specified at 50°
C, so in that sense the following results are slightly conservative. The MTBF values shown below are for a 40° C in
an office or telecommunications environment. Higher temperatures and other environmental stresses (extreme
altitude, vibration, salt water exposure, etc.) lower MTBF values.

»

System MTBF: 264194 hours @ 40°C