Connecting a Flat Panel
To determine whether your flat panel is supported check the KONTRON website for panel lists. We regularly
update the list of panels that have been tested with the MOPSlcdLX.
If you use one of those adapters supplied by KONTRON configuration is easy:
❶
Check whether you have the correct adapter and cable for the panel you plan to use. Inspect
the cable for damages. Disconnect the power from your system.
❷
Connect the cable to the flat panel connector X12000 on the MOPSlcdLX and connect the other
end to your JILI adapter - connect the JILI adapter and the display.
❸
Connect the backlight converter.
❹
Supply power to your system.
❺
If no image appears on your display connect a CRT monitor to the CRT connector.
❻
If necessary program the EEPROM on the JILI cable with the matching configuration data.
❼
If you still do not see improvement consider contacting the dealer for technical support.
8.4
Available Video Modes
The following list shows the video modes supported by the graphics controller with maximum frame buffer
size. When configured for saller frame buffers and/or using a flat panel on the JILI interface not all of the
video modes listed below may be available. Capability depends on system configuration and on display
capabilities. Different operating systems also may not support all listed modes by the available drivers.
Video Mode
Type
Characters/Pixels
Colors
00h/01h
Text
40 x 25
16
02h/03h
Text
80 x 25
16
04h/05h
Graphic
320 x 200
4
06h
Graphic
640 x 200
2
07h
Text
80 x 25
2
0Dh
Graphic
320 x 200
16
0Eh
Graphic
640 x 200
16
0Fh
Graphic
640 x 350
2
10h
Graphic
640 x 350
4
11h
Graphic
640 x 480
2
12h
Graphic
640 x 480
16
13h
Graphic
320 x 200
256