Vibration, Schock – Kontron AM4311 User Manual
Page 21

Introduction
Page 6
AM4311 User Guide
1.3.8
Vibration
The board is designed to meet the following requirements according to IEC 60068-2-6, Bellcore GR-63, Sec-
tion 4.4 and MIL-STD-810E, Method 514:
• Operating
• 5Hz to 100Hz: 1G @ 0.25 Octave/minute
• 100HZ to 500Hz: 1G @ 1 Octave/minute
• 5Hz @ 0.01 g2 /Hz to 20 Hz @ 0.02 g2 /Hz (slope up)
• 20Hz to 500 Hz @ 0.02 g2 /Hz (flat)
• 3.13 g RMS, 10 minutes per axis for all 3 axes
• Non-Operating
• 5Hz to 50Hz: 0.5G @ 0.1 Octave/minute
• 50Hz to 500Hz: 3G @ 0.25 Octave/minute
1.3.9
Schock
The board is designed to meet the following requirements IEC 60068-2-27 and MIL-STD-810E, Method 516:
• Operating:
30G/11 ms half sine
• Non-Operating:
50G, 170 inches/second trapezoidal
1.3.10
Safety
CB report to IEC 60950-1, complies with EN/CSA/UL 60950-1.
1.3.11
Electromagnetic Compatibility
The board is designed to meet or exceed the following specifications/requirements (assuming an adequate
carrier/chassis):
• CFR 47, FCC Part 15, Subpart B
• Telcordia GR-1089-Core-Issue 3 and SR-3580 Issue 2
• EMC Directive 89/336/EEC (Europe)
• EN55022 (Europe)
• EN55024 (Europe)
• EN61000-4-2 + A1 + A2
• EN61000-4-3 + A1
• EN300 386 V1.3.3, Electro Magnetic Compatibility (EMC) Requirements for Public Telecommunication
Network Equipment; Electromagnetic Compatibility (EMC) Requirements.
1.3.12
MTBF
MTBF is >170,000h@40°C, calculations based on Bellcore/Telcordia SR-332.