At8902 introduction – Kontron AT8902 User Manual
Page 22
AT8902
Introduction
Page 1 - 8
AT8902 User Guide
General
Mechanical
•
8U form factor mechanically compliant to PICMG 3.0
•
Single Slot (6HP)
•
2 standard full height/single width AMC Slots
•
280 mm x 322 mm (11.024“ x 12.677“)
•
Weight: 1.9 kg (4.2 Ibs)
Power Requirements
•
Typical: 45W
•
Maximum (with 2 AMCs and RTM): 150W
•
AMCs may consume up to 75W
•
Operating Voltage: -38 to -72VDC
Temperature
Designed to meet or exceed the following (Characteristics with AMC):
•
Air Flow: 30 CFM min
•
Operating: 0°C to +55°C (32°F to 131°F)
•
Non-operating: -40°C to +70°C (-40°F to 158°F)
Humidity
Designed to meet or exceed the following:
•
Bellcore GR63, Section 4.1
•
Operating: 15%-90% (non-condensing) at 55°C (131°F)
•
Non-Operating: 5%-95% (non-condensing) at 40°C (104°F)
Altitude
Designed to meet or exceed the following:
•
Operating: 4000 m (13123 ft))
•
Non-Operating: 15000m (49212 ft)
Vibration
Designed to meet or exceed the following:
•
Bellcore GR-63, Section 4.4
•
Operating: 1.0G, 5-500Hz each axis
•
Non-operating: 0.5G, 5-50Hz; 3.0G, 50-500Hz each axis
Shock
Designed to meet or exceed the following:
•
DIN/IEC 60068-2-27
•
Bellcore GR-63, Section 4.3
•
30G, half-sine 11ms, each axis
Table 1-3: AT8902 Main Specifications (Continued)
AT8902
SPECIFICATIONS