beautypg.com

1 voltage ramp, 2 voltage sequencing requirements, 3 rise time diagram – Kontron CP932 User Manual

Page 49: Voltage ramp - 5, Voltage sequencing requirements - 5, Rise time diagram, Voltage ramp of the cp3-sve180 ac power supply - 5, Cp932 power considerations

background image

CP932

Power Considerations

ID 30048, Rev. 01

© 2005 Kontron Modular Computers GmbH

Page 5 - 5

3004

8.01.UG.VC.050622/19130

1

P R E L I M I N A R Y

5.4.1

Voltage Ramp

Power supplies must comply with the following guidelines, in order to be used with the CP932.

• Beginning at 10% of the nominal output voltage, the voltage must rise within

> 0.1 ms to < 20 ms to the specified regulation range of the voltage. Typically:
> 5 ms to < 15 ms.

• There must be a smooth and continuous ramp of each DC output voltage from

10% to 90% of the regulation band.

• The slope of the turn-on waveform shall be a positive, almost linear voltage increase and

have a value from 0 V to nominal Vout.

5.4.2

Voltage Sequencing Requirements

The +5 VDC output level must always be equal to or higher than the +3.3 VDC output during
power-up and normal operation.

5.4.3

Rise Time Diagram

The following figure illustrates an example of the recommended voltage ramp of a CompactPCI
power supply for all Kontron boards delivered up to now.

Figure 6-1: Voltage Ramp of the CP3-SVE180 AC Power Supply