beautypg.com

4 technical specifications, Cp932 main specifications - 9, Cp932 introduction – Kontron CP932 User Manual

Page 25

background image

CP932

Introduction

ID 30048, Rev. 01

© 2005 Kontron Modular Computers GmbH

Page 1 - 9

3004

8.01.UG.VC.050622/19130

1

P R E L I M I N A R Y

1.4

Technical Specifications

Table 1-2: CP932 Main Specifications

GROUP

TYPE

DESCRIPTION

Controllers

BCM5385 / BCM5388
Gigabit Ethernet Switch
Controller from Broadcom

On the five-channel variant:
Broadcom BCM5385 high-performance, five-port Gigabit Ethernet
switch controller with

• Four integrated PHYs, and
• One RGMII interface

in 324-pin FBGA package.
On the six-channel variant:
Broadcom BCM5388 high-performance, eight-port Gigabit Ethernet
switch controller with

• Four integrated PHYs, and
• Four RGMII interfaces

in 324-pin FBGA package.

PCI Gigabit Ethernet Con-
troller

Only on the six-channel variant:

• Intel 82541PI PCI Gigabit Ethernet controller

Internal

Interfaces

PCI Bus

Only on the six-channel variant:

• 32-bit, 33/66 MHz PCI bus compliant with the CompactPCI Spec-

ification, V. 2.0, Rev. 3.0

• universal signaling: 3.3 V or 5 V V(I/O)
• PCI interrupt INTA#

External

Interfaces

Front Panel Connectors

• five, 8-pin, female, RJ45 connector(s)
• The CP932 supports up to five channels of full or half duplex

10Base-T, 100Base-TX, 1000-Base-T Ethernet operation with up
to 100 meters cable length.

Onboard Connectors

• One CompactPCI connector
• One ATX power connector (only on the five-channel variant)

Indicators

Front Panel LEDs

Two bicolor LEDs per channel are provided for indicating the
Ethernet channel operational status:

ACT LED (Green):

• ACT ON:

Ethernet Link

• ACT OFF:

No Ethernet Link

• ACT BLINKING:

Ethernet Activity

SPEED LED (Green/Yellow):

• SPEED ON (green):

100 Mbit

• SPEED ON (yellow):

1000 Mbit

• SPEED OFF:

10 Mbit

Thermal
Aspects

Heat Sink

The CP932 is fitted with an optimally designed heat sink to
ensure overtemperature protection.

Forced Air Flow

For proper operation at the specified temperatures, a minimum
airflow of 1 m/s is required.