beautypg.com

Pyromaster, H33bdvrrn/p, Hearth – Vermont Casting H33BDVRRN User Manual

Page 5: Mantels, Clearance to combustibles mantel chart

background image

5

Pyromaster

©

H33BDVRRN/P

10004798

Appliance

Top.............................................. 0” (0 mm)
Bottom........................................ 0” (0 mm)
Side............................................ 0” (0 mm)
Back........................................... 0” (0 mm)

Venting
Concentric sections of DV Vent

Top, bottom & sides.................. 1” (25 mm)

Rear Vent Applications:

Top............................................ 2”
Sides......................................... 1”
Bottom...................................... 1”

Hearth

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12” (305mm) or more from
the front of the fireplace.

Cold climate installation recommendation:

When installing this unit against a
noncombustible exterior wall or chase, it
is mandatory that the outer walls be
insulated to conform to applicable
insulation codes.

Mantels

The height that a combustible mantel is fitted above
the fireplace is dependent on the depth of the mantel.
This also applies to the distance between the mantel
leg (if fitted) and the fireplace.

For the correct mounting height and widths refer to
Figures 3a and 3b, and the following Mantel Charts.

The fitting of a bay window trim kit does not effect the
distances and reference points referred to in the
diagram and chart.

Noncombustible mantels and legs may be installed at
any height and width around the appliance. When
using paint or lacquer to finish the mantel, such paint
or lacquer must be heat resistant to prevent
discoloration.

Clearance to Combustibles

Mantel Chart

Mantel Shelf

Mantel from Top

Ref.

or Breast Plate

Ref. of Comb. Chamber

Depth

V

10” (254mm)

A

17” (432mm)

W

8” (203mm)

B

15” (381mm)

X

6” (152mm)

C

13” (330mm)

Y

4” (101mm)

D

11” (279mm)

Z

2” (50mm)

E

9” (229mm)

A

B

C

D

E

V

W

X

Y

Z

Fireplace

Top Louvre
Assembly

Top of Combustion
Chamber

Bottom of Door Triim

CFM146

Fig. 3a Combustible mantel minimum installation.

J

F

G

H

I

Mantel
Leg

O

N

M

L

K

Fig. 3b Combustible mantel leg minimum installation.

Mantel

Mantel Leg from Side

Ref.

Leg Depth

Ref.

of Comb. Opening

F

10” (254mm)

K

11

¹⁄₂

” (292mm)

G

8” 9203mm)

L

9

¹⁄₂

” (241mm)

H

6” (152mm)

M

7

¹⁄₂

” (191mm)

I

4” (101mm)

N

5

¹⁄₂

” (140mm)

J

2” (50mm)

O

3

¹⁄₂

’” (89mm)

CFM170

Black
Surround
Face

Side of Combustion
Chamber

CFM164a

This manual is related to the following products: