beautypg.com

Archived 4/2/10 – ETS-Lindgren HI-3510 RF Radiation Badge Broadband Electromagnetic Radiation Detector (Archived) User Manual

Page 14

background image

HI

n

3510 Manual

Page — 9

Should the unit detect a field that exceeds the preset

alarm warning level, the unit will start to beep and flash.

The beep and the flash rate are directly proportional to

the RF field strength above the alarm set value (see 3-4-

2). Note that once the alarm starts, it will latch at the

minimum flash rate, continuing to warn of an over-

exposure even if the RF field that caused the alarm is no

longer present. In order to reset the alarm function, the

unit must be turned OFF and back ON using the ON-OFF

switch. For information concerning disabling the latch

function, refer to paragraph 3-4-4. For information

concerning "Instantaneous" vs "Average" measurement

modes, refer to paragraph 3-4-3.

Archived 4/2/10